156
submitted 2 years ago by 111000@reddthat.com to c/askmen@lemmy.world
you are viewing a single comment's thread
view the rest of the comments
[-] Darkassassin07@lemmy.ca 26 points 2 years ago

That works great until you accidentally connect one side of the split-phase service with the other side... Your male-to-male cable becomes a short across 240vac.

Also: if you don't turn the main breaker off first, you are now back-feeding power into lines the local linemen expect to be dead, potentially electrocuting them... This is why specific receptacles connected with a generator interlock kit (breaker that can only be turned on while the main is off) are used.

this post was submitted on 20 Dec 2023
156 points (100.0% liked)

Ask Men

1852 readers
2 users here now

A community to Ask Men questions and discuss any and all issues relating to them.

Unlocking Perspectives, Advice, and Empowerment for Men Everywhere.

Rules

Follow the rules of lemmy.world, which can be found here.

Additionally:

  1. Be respectful
  2. Try to engage in a positive & constructive manner
  3. No harassment, hate speech, or trolling
  4. Use appropriate language & tone.
  5. Share relevant content.
  6. Follow guidelines and moderators' instructions
  7. Report content that violates rules or needs moderator attention

Notes

Would you like to help with moderating AskMen? Send a PM to the top mod.

founded 2 years ago
MODERATORS